article.page.titleprefix
Experimental and transient CFD analysis of parallel-flow solar air collectors with paraffin-filled recyclable aluminum cans as latent heat energy storage unit

dc.contributor.authorTuncer, Azim Doğuş
dc.contributor.authorAmini, Ali
dc.contributor.authorKhanlari, Ataollah
dc.date.accessioned2023-12-13T11:36:39Z
dc.date.available2023-12-13T11:36:39Z
dc.date.issued2023-10-15
dc.descriptionPublished by Journal of Energy Storage, https://doi.org/10.1016/j.est.2023.108009, Azim Doğuş Tuncer, Department of Energy Systems Engineering, Burdur Mehmet Akif Ersoy University, Burdur, Turkey, Ali Amini, Department of Automotive Engineering, Atilim University, Ankara, Turkey, Ataollah Khanlari, Department of Mechanical Engineering, Faculty of Engineering, Tarsus University, Tarsus, Mersin, Turkey.
dc.description.abstractIn the present study, it is aimed to improve the overall performance of a parallel-flow solar air collector (PSC) using phase change material (PCM)-based latent heat energy storage unit and recyclable materials. In the simulation part of this work, two PSCs including a collector without modification and a collector equipped with PCM filled aluminum cans have been analyzed. The simulation part of the current work is handling the flow of air through the collectors and melting-solidification of PCM material inside the aluminum cans. Considering the simulation study results, three different PSC configurations have been manufactured including an unmodified PSC, a PSC with PCM-filled aluminum cans on the front side of the absorber and a PSC with PCM-filled aluminum cans on both sides (back and front) of the absorber surface. According to the results of the analyses, utilizing PCM-filled aluminum cans in both surfaces of the absorber plate of the PSC improved numerically and experimentally obtained exergetic efficiency values as 61.70% and 74.03%, respectively. Moreover, enviro-economic analysis has been conducted within the scope of this work. The payback periods of the analyzed systems were between 2.17 and 2.43 years. Employing PCM in the both sides of the absorber surface decreased the payback time of the system as 10.69% in comparison to the conventional PSC. Moreover, using PCMs on the single and double side of the absorber plate improved the annual carbon dioxide savings as 22.68% and 35.42%, respectively.
dc.identifier.citationhttp://hdl.handle.net/20.500.14411/1893
dc.identifier.issn2352-152X
dc.identifier.urihttps://doi.org/10.1016/j.est.2023.108009
dc.language.isoen
dc.publisherJournal of Energy Storage
dc.relation.ispartofseries70
dc.subjectSolar air collector, Aluminum can, Latent heat energy storage, Computational fluid dynamics, Melting-solidification
dc.titleExperimental and transient CFD analysis of parallel-flow solar air collectors with paraffin-filled recyclable aluminum cans as latent heat energy storage unit
dc.typeArticle
dspace.entity.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
a1-Experimental and transient CFD analysis of parallel-flow solar air-2023-Yazar Versiyonu.pdf
Size:
3.11 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: